How to Bypass the On/Off Switch on Generator

Updated:

With some basic knowledge and a few tools, it’s straightforward to bypass the on/off switch and get your generator running again.

This article provides a comprehensive guide on diagnosing a faulty on/off switch, bypassing it temporarily, and replacing it for a long-term solution. Some may argue that a solar generator could also be a much better longer term solution. Not only better for you, but for the environment as a whole.

We’ll also discuss other common generator problems and how to tackle them, including bypassing the oil sensor shutdown switch.

Let’s start by discussing how to diagnose problems with your generator’s on/off switch.

Diagnosing On/Off Switches

The on/off switch is a crucial component in a generator. The generator may not start or shut down during operation if faulty. Here’s how you can easily diagnose the on/off switch of your generator:

Visual Inspection

Start by visually inspecting the on/off switch. Look for any signs of physical damage, such as cracks or wear. If the switch appears damaged, it may need to be replaced.

Multimeter Test

Diagnosing a generator on/off switch using a multimeter

You can also use a multimeter to test the on/off switch.

First, set the multimeter to read ohms, usually represented by an Omega symbol. If your multimeter doesn’t have auto-ranging, set the dial to a low resistance reading you think you might read.

Next, remove the generator’s front panel and unplug the cables connected to the switch. Attach the multimeter leads to the terminals of the on/off switch.

With the switch in the ‘off’ position, the multimeter should read ‘open’ or ‘infinite’ resistance. When you turn the switch to the ‘on’ position, the multimeter should read close to 0 ohms, indicating that the circuit is closed and the switch works properly.

If the reading doesn’t change when you toggle the switch, or if the readings are inconsistent with these principles, the switch is likely faulty.

Bypassing the On/Off

Bypassing the on/off on a generator may be needed when the switch is faulty and the generator needs to be started immediately. This section provides a simple method to bypass the switch and start your generator.

But remember that this should only be a temporary solution. Ideally, you should replace the on/off switch with a new one.

  1. Prepare Your Tools: You’ll need an insulated screwdriver and a jumper wire with alligator clips at both ends. The jumper wire will directly connect the starter motor and the on/off switch.
  2. Remove the Panel: The on/off switch is usually on the generator’s front panel. Generators typically have four faceplate screws. Remove these screws to access the switch. This will provide clearer access to the wires connected to the on/off switch.
    Screws and on/off switch on the front panel
  3. Identify the Wires: Locate the wires connected to the back of the switch. There are typically two wires which we need to connect directly.
    On/off swtich terminals and wires to be directly connected.
  4. Create a Direct Connection: Place the ends of the jumper wire on the two disconnected wires after carefully removing insulation from them. This bypasses the on/off switch.
  5. Engage the Starter Motor: Now, you can start the generator. If your generator has a pull cord, you will need to pull this cord to start the generator. If it has an electric start, you must press the start button.
  6. Disconnect After Use: Remember to disconnect the jumper wire to shut down the generator once you’re done using the generator. This is crucial for safety reasons.

Replacing the On/Off Switch

While bypassing the on/off switch can provide a quick fix and get your generator running, the long-term solution is replacing the on/off switch.

This straightforward process can be done with a few basic tools. Here’s a step-by-step guide on how to do it:

  1. Remove the Panel: To access the on/off switch, remove the generator’s front panel.
  2. Remove the Old Switch: The old switch might be glued in due to the generator’s vibration. Carefully remove this glue and then remove the terminals at the back of the switch. Pinch the sides of the switch and push it through the front. You might need to tap it lightly to pop it out.
  3. Check the New Switch: Before installing the new switch, ensure its current carrying capacity is either the same or higher than the old one. The new switch might be slightly bigger than the old one. If this is the case, you’ll need to file the hole in the faceplate to make it fit.
  4. Install the New Switch: Connect the terminals once the new switch fits. Make sure to get the orientation correct. The new switch should be inserted the same way the old switch was. Press the new switch into place. You can add some glue to counteract the vibration of the generator.
  5. Test the New Switch: After installing the new switch, test it to ensure it’s working correctly. When the generator is on, the circuit should be open. When the generator is off, the circuit should be closed.
  6. Reinstall the Panel: Once the new switch is installed and working, you can reinstall it and attach it to the bolts.

Can you Bypass the On/Off Switch On a Solar Generator?

Solar generators are fundamentally different from traditional gas or diesel generators, primarily due to their electronic controls. Rather than using a manual on/off switch, they incorporate electronic circuitry and separate power buttons for individual AC, DC, and USB outputs, all controlled by an Electronic Control Unit (ECU).

This advanced setup means that it’s impossible to bypass the power buttons on a solar generator in the same way you might a manual switch on a traditional generator. If the power buttons or the ECU are faulty, the generator may not function correctly or at all.

Given the complexity of these systems, you should leave the troubleshooting and repairs to a professional, particularly for issues relating to the ECU. Trying to bypass the switches or directly interface with the ECU can be risky, potentially damaging the unit and voiding your warranty.

However, the bright side is that these electronic controls tend to be more robust and less prone to failures than manual switches, making repairs less frequent.

Other Common Generator Problems

If bypassing or replacing the on/off switch does not resolve your generator’s startup issues, other factors could be at play.

Like any machine, generators can encounter various problems that may prevent them from starting up properly. Here are some common problems that you might encounter:

Faulty Ignition Switch

A faulty ignition switch can prevent the generator from starting. Regular inspection and maintenance can help identify and rectify any issues with these switches.

Low Oil Level

Generators require a sufficient amount of oil to operate smoothly. If the oil level is low, the generator may not start or shut down during operation.

Always ensure that the oil level is adequate before starting your generator.

Insufficient Fuel

A generator won’t start if it’s out of gas. Always check the gas tank to ensure there’s enough fuel for operation.

Remember to use fresh gasoline to avoid clogs and hard starts.

Incorrect Choke Lever Position

The choke lever should be set to “closed” during startups and then moved to “open” once the engine warms up.

If the choke lever is in the wrong position, it can prevent the generator from starting.

Fuel Valve Issues

If the fuel valve is closed or clogged, fuel can’t reach the carburetor, preventing the generator from starting.

Ensure that the fuel valve is open and that there are no clogs in the fuel line.

Clogged Carburetor

If a generator has been stored for a long time without draining the carburetor, it can become clogged with old gasoline, preventing the generator from starting.

Regular maintenance and cleaning can prevent this issue.

Faulty Spark Plug

Over time, deposits can build up on the spark plug, affecting its performance.

Regularly check the spark plug for deposits and clean or replace it as necessary.

Malfunctioning Low-Oil Sensor

If the low-oil sensor isn’t working correctly, it can prevent the generator from starting, even if the oil level is adequate.

Check the sensor and replace it if necessary.

Dead Battery

The battery may lose its charge over time due to insufficient use for electric start generators.

If this happens, you may need to recharge the battery or start the generator using the pull starter.

Start the generator using the pull starter.

Plugged-in Electronics During Startup

Always ensure that all electrical devices are unplugged before starting the generator. Having devices plugged in during startup can cause issues.

Dirty Air Filter

A dirty air filter can prevent the necessary air from reaching the carburetor, affecting the generator’s performance.

Regularly check, clean, or replace the air filter as needed.

Bypassing the Oil Sensor Shutdown Switch

Just like the on/off switch, another common issue that can arise with generators is with the oil sensor shutdown switch.

This switch protects your generator by automatically shutting it down when the oil level drops too low.

However, there can be situations where this sensor might malfunction, indicating a low oil level even when the oil is sufficient. In such scenarios, a temporary solution could be to bypass the oil sensor shutdown switch.

Here’s a step-by-step guide on how to do it:

  1. Safety First: Before starting, ensure the generator is turned off and disconnected from any power source. Avoid touching hot parts, and be careful when working around gasoline.
  2. Locate the Oil Sensor: The oil sensor is usually located in the engine bay of the generator. Look for a wire connected to the sensor. This wire sends the oil level signal to the generator’s control system.
  3. Disconnect the Sensor: To bypass the sensor, disconnect the wire from the sensor. This will prevent the sensor from sending oil-level signals to the generator’s control system. Use a piece of tape to cover the end of the wire to prevent it from touching the ground or any other part of the generator.
  4. Start the Generator: Start the generator with the oil sensor disconnected. The generator should start and run normally, as the disconnected sensor will not receive low-oil-level signals.
  5. Reconnect the Sensor: The sensor should reset once the generator is running and the oil has warmed up. At this point, you can reconnect the wire to the sensor. This will allow the sensor to resume monitoring the oil level.